Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
each office [verify with user].
2-5.4.2.1 Function: Private office or systems furniture workstation for use by S-3 personnel.
2-5.4.2.2 Adjacency requirements: Adjacent to S-3 Clerical /Central Files.
2-5.4.2.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair, and one desk chair. If systems furniture panels are provided in lieu of drywall
partitions, provide workstation type ___.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.4.2.5 Other requirements: Exterior window is desirable. If drywall partitions are used,
provide 914 mm [3'-0"] wide door into each room; door shall have entry function (F81) lockset.
Drywall partitions shall have minimum STC rating of 49.
S-3 Clerical/Central Files. Provide one; 94.8 m2 [1,020 sf]. S-3 Clerical/Central
2-5.4.3
Files shall be accessed from the lobby or corridor. The area shall have direct access to S-3
private offices. Occupants: 8 staff , and occasional visitors.
2-5.4.3.1 Function: Open office area for S-3 admin staff; access to S-3 offices.
2-5.4.3.2 Adjacency requirements: Adjacent to lobby or corridor. Adjacent to S-3 private
offices.
2-5.4.3.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate eight
type ___ systems furniture workstations.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.4.3.5
Other requirements:
Provide 914 mm [3'-0"] wide door into room; door shall have entry function (F81) lockset.
Exterior window is desirable. Partitions shall have minimum STC rating of 49. Minimum ceiling
height 2642 mm [8'-8"].
2-5.5
S-4 Section. Provide one group of offices. In a two-story building locate S-4
Section on the first floor. Locate S-4 Section adjacent to PAC Section.
S-4 Officer. Provide one; 8.8 m2 [95 sf]. Room shall be accessed through the S-4
2-5.5.1
Clerical/Central Files area. Occupants: 1, and occasional visitors.
2-5.5.1.1 Function: Private office for S-4 officer.
SOW-69