CEMP-E
TI 810-32
10 January 2002
SEALENT WITH BACKING ROD
MATCH CURB
1/2 "
1 1/2 "
8" MIN.
6" MIN.
6" MIN.
1" MIN.
@ ROADS
VARY FROM 90^ IF JOINT
OPENING WILL EXCEED 1/2 "
4
DETAIL
B
NO SCALE
STD TRENCH COVER
2'
SYMMETRICAL
ABOUT
6"
BITUMINOUS
>
CURB&GUTTER
1"
1/2 "
PAVEMENT
TRENCH COVER
UNIT BEYOND
1/2 " R
3/4 " R
1"
8" MIN.
8"
1'
1/2 " SEAL
5 11/16 "
EXPANSION
SEE TRENCH COVER
JOINT
PROVIDE EXPANSION
REINFORCEMENT
MATERIAL BETWEEN
#4-5@ EVEN SPACES, WIDTH
TRENCH CURB AND
OF TRENCH COVER
EXISTING CURB
#4@ 6" O.C.
SECTION
TYPICAL CURB & GUTTER
4
REINFORCING DETAIL
NO SCALE
NO SCALE
TRENCH CROSSING WITH CURB AND GUTTER
NO SCALE
NOTE TO THE DESIGNER:
TRENCH CONCRETE THICKNESSES AND REINFORCEMENT SHOWN MUST BE VERIFIED FOR
EACH DESIGN BY THE DESIGNER.
Fig. 4-11. Trench Crossing with Curb and Gutter.
4-14