UFC 4-022-01
25 May 2005
processing. Assume that approximately 12-20 people can be processed each
hour on average per processing station.
Include a computer station with networking and Internet access for each
processing station.
Provide photo ID capability at each processing station. Install a photo
backdrop. Provide wiring at each processing station for a duress alarm.
6-17.4 Administration Office
Provide an enclosed office for two workstations and a filing cabinet.
Provide video surveillance equipment for the interior and exterior areas of the
Visitors Center.
Provide Internet connectivity, telecommunications, a closed-circuit television
system, and a radio battery recharging area.
6-17.5 Break Room
Locate the break room so that it is out of the direct line of sight of the
waiting/seating area.
Provide seating for four SF personnel.
6-17.6 Restrooms
Provide men's and women's restrooms for public and security personnel use
per ADAAG requirements. Provide accommodations for baby-changing
stations in each restroom.
6-17.7 Environmental Control
Provide heating and cooling appropriate for personnel, the electronic and electrical
systems or fixtures, and the security support equipment. The HVAC requirements
should be based on existing service design guidance and installation requirements.
6-18
PEDESTRIAN CONSIDERATIONS
Some installations have a significant pedestrian volume. When pedestrian access
control is required, ensure that proper sidewalk and safety provisions direct pedestrian
traffic to the Access Control Zone and separate it from vehicular traffic. Design
pedestrian access to ensure security personnel maintain visual contact with the
pedestrians as they approach the ECF. Plan sidewalks to integrate into the existing site
layout and accommodate new facilities. Breaks may be provided in the passive barriers
surrounding the ECF to allow pedestrian access to the ECF. Any break in the passive
barrier should not exceed 3 ft (1 m) in width. Provide sidewalks with a minimum width
of 4 ft (1.2 m). Crosswalks should be 6 ft (1.8 m) in wide.
Where warranted based on pedestrian usage, incorporate turnstiles or similar devices
that can be automated to facilitate authorized access control. Ensure turnstiles
6-40