MIL-HDBK-1024/1
c)
Exterior security lighting.
8.2.6
measures for external security. If the facility is located within a
restricted area of a lower level of security or is located remote and outside
of an established restricted area, provide additional measures to meet the
minimum security requirements for the level of security assigned to the
facility. The level of security and the designer's responsibility for
particular security elements shall be designated in the IDSEP. Refer to par.
2.6.
8.2.7
containers in the supply room. Provide storage for hazardous wastes in a
covered outdoor, water sealed concrete contaminant. Design the containment to
hold a spill equal to the largest container plus 10 percent and the waste
containers. Provide a fence and signs stating "Hazardous Waste Storage."
8.2.8
Additional Design Criteria.
Refer to Section 2 for facility design
requirements not addressed above.
8.3
Anti-Submarine Warfare Operations Center (ASWOC)
8.3.1
Function. The ASWOC building houses the Navy Command and Control
Systems (NCCS) which provide the anti-submarine warfare (ASW) sector commander
with the facilities and capabilities to plan and execute assigned missions,
which include ASW, anti-surface warfare (ASUW), over the horizon targeting
(OTHT), maritime surveillance, mining, search and rescue, drug enforcement
operations, special projects, power projection, battle group/amphibious task
force/convoy support, and flight crew training. ASWOCs operate across the
entire threat environment from peacetime surveillance through low intensity
8.3.2
Location. Locate the ASWOC building adjacent to the Naval
Oceanography Command (NAVOCEANCOM) and Special Information Command (SPINTCOM)
activities and as close as possible to the patrol squadron hangar. Locate
within 1,000 feet of a suitable site for a AN/SMQ-11 antenna.
8.3.3
Architectural and Structural Requirements. See Facility Plate
141-42 (Sheets 1 through 7 of 7). Provide the following:
a)
A one- or two-story building.
b) Blast hardened construction. Refer to NAVFAC P-397, Structures
to Resist the Effects of Accidental Explosions; DM-2.08, Blast Resistant
Structures; and MIL-HDBK-1013/1.
143