MIL-HDBK-1024/1
8.4.3
Architectural and Structural Requirements. The facilities are
designated as small or medium/large buildings. See Facility Plate 141-12
(Sheets 1 through 5 of 5). Provide the following:
a)
b)
Ball bearing pallet platform in medium/large building.
c) Clear ceiling height of 16 feet in cargo handling area with
overhead doors open.
d)
Dust pickup, conveying, and collection system in carpentry shop.
e)
Weighing scales.
f)
Overhead hoist (capacity determined by user).
g)
Compressed air system (capacity determined by user).
h)
Built-in furnishings including counters, benches, and storage
racks.
i) Administration and personnel spaces with one-hour fire
separation from cargo/work areas.
j)
Facility and restroom areas readily accessible by the physically
handicapped.
k)
Additional area to accommodate storage of malfunctioning
equipment.
8.4.3.1
Structure. Design roof framing system to support suspended
equipment and overhead hoist.
8.4.3.2
Wire Mesh Partitions. Construct wire mesh partitions with doors for
security cage. Refer to NFGS-10605, Wire Mesh Partitions.
8.4.3.3
Interior Doors.
Provide insulated doors between personnel spaces
and cargo handling areas.
8.4.3.4
Overhead Doors.
Provide electrically operated overhead doors.
Pre-engineered Buildings. Consider using a pre-engineered metal
8.4.3.5
building. Refer to NFGS-13121, Pre-engineered Metal Buildings (Rigid Frame).
8.4.4
Mechanical Requirements
153