Home
Download PDF
Order CD-ROM
Order in Print
Home
>
United Facilities Criteria CD 2
>
> Design: Covered Storage - index
Design: Covered Storage - index
Design: Covered Storage - ufc_4_442_01n0001
Unified Facilities Criteria (UFC) - ufc_4_442_01n0002
Foreword - ufc_4_442_01n0003
Contents - ufc_4_442_01n0004
Chapter 1 Introduction - ufc_4_442_01n0005
Military Handbook - ufc_4_442_01n0007
Abstrack - ufc_4_442_01n0009
Foreword - ufc_4_442_01n0011
Storage Criteria Manuals
Contents - ufc_4_442_01n0013
Contents - Cont'd - ufc_4_442_01n0014
Contents - Cont'd - ufc_4_442_01n0015
Contents - Cont'd - ufc_4_442_01n0016
Contents - Cont'd - ufc_4_442_01n0017
Contents - Cont'd - ufc_4_442_01n0018
Contents - Cont'd - ufc_4_442_01n0019
Contents - Cont'd - ufc_4_442_01n0020
Contents - Cont'd - ufc_4_442_01n0021
Figures - ufc_4_442_01n0022
Figures - Cont'd - ufc_4_442_01n0023
Tables - ufc_4_442_01n0024
Section 1: Criteria for Convered Storage Buildings
Definitive Drawings
Flammable/Hazardous Storehouse (Code 441-30)
Ammunition Storage (Code 420)
Section 2: Planning Factors - ufc_4_442_01n0030
Grading and Drainage
Transaction Activity
Figure 1 System Selection Flowchart
Determine Area
System Considerations
Table 1 Administrative and Supervisory Offices and Support Area Space Requirements
Receiving Office - ufc_4_442_01n0037
Figure 2 Typical Receiving Office (Functional Dimensions)
Figure 3 Typical Shipping Office (Functional Dimensions)
Traffic Flow
Value of Existing Assets Replaced
Figure 4 Facility Design Process Flowchart
Architectural Design
Section 3: building Requirements
Table 2 Special Requirements for Convered Storage Buildings
Table 2 Special Requirements for Convered Storage Buildings - Cont'd
Figure 5 Building Elevation Parameters
Building Spacing
Figure 6 Truck Apron Criteria (Functional Dimensions)
Figure 7 Building Protection Devices
Table 3 Truck and Rail Vehicle and Dock Heights
Figure 8 Truck Dock Configurations
Figure 9 Typical Truck Dock (Section)
Figure 10 Typical Truck Dock (Plan)
Figure 11 Truck Apron Section
Figure 12 Door Size Characteristics
Rail Docks
Figure 13 Rail Car Characteristics
Table 4 Dock leveler Life (Years) Based on Impact Loading
Figure 14 Truck Dock Weather Seals
Canopy
Figure 15 Truck Dock Canopy
Figure 16 Trailer Restraint System
Conventional Construction - ufc_4_442_01n0064
Figure 17 Exterior Wall Detail
Fixed Partitions
Electrical - ufc_4_442_01n0067
Figure 18 Floor Loading Nomograph
Static Load
Wire Guide Requirements
Separation Distance
Figure 19 Standard Navy In-Rack Sprinkler Arrangement
Figure 20 Standard Navy Face and Longitudinal Flue Sprinkler Mounting
Figure 21 Standard Navy Flam/Haz Flue Sprinkler System
Water Supply - ufc_4_442_01n0075
Battery Charging and Handling Operations
Figure 22 Battery Charging Area (Open Locations)
Figure 23 Battery Charging Area (One-Entrance Room)
Figure 24 Typical Battery Charger Installation
Pallet Racks
Figure 25 Pallet Rack Terminology
Figure 26 Navy/DOD Pallet Arrangement
Figure 27 Standard Pallet Rack Elevation
Figure 28 Pallet Rack Fire Protection Terminology
Figure 29 Pickup and Delivery (P&D) Stations
Figure 30 Typical Rail Guidance System
Figure 31 Typical Wire Guidance System
Table 5 Building Bay Size Comparizon
Universal Bay Size
Figure 32 Building Column Spacing Parameters
Table 6 Required Clear building Heights
Alarm Systems - ufc_4_442_01n0092
Figure Typical Safety markings
Design For Handicapped
Heating Plant
Table 7 Lighting Standards for Federal Supply Service Distribution Facilities
Lighting Fixtures
Section 4: Flammable/Hazardous Materials Warehouse
Other Criteria
Segregation of Materials
Caustics
Figure 34 Flammable/Hazardous Materials Storage Segregation Layouts
Combined Shed Storage
Table 8 General Requirements for Hazardous Materials Storage Facilities
Lightning Protection - ufc_4_442_01n0105
Figure 35 Spill Capture/Containment System
Figure 36 Electronic Guide Wire Crossing
Containment
Section 5: Heavy Materials Warehouse
Section 6: Cold Storage Warehouse
Selection - ufc_4_442_01n0111
Sealants, Fasteners, and Adhesives
Sprinklers
Table 9 Pallet Storage Quantities for Cold Storage Warehouses
Storage Height
Definition
Employee Service Areas
Electrical - ufc_4_442_01n0118
Drainage/Containment
Section 8: Controlled humidity Warehouse
Personnel Doors - ufc_4_442_01n0121
Section 9: Modernization of Existing General Warehouse Buildings
Concrete Members
Appendix A Illustrations of Typical Cold Storage Construction and Insulation
Figure A-1 Cold Room Insulation Datails 1
Figure A-2 Cold Room Insulation Datails 2
Figure A-3 Cold Room Insulation Datails 3
Figure A-4 Cold Room Insulation Detail 4
Figure A-5 Cold Room Insulation Datails 5
Figure A-6 Cold Room Insulation Datails 6
Figure A-7 Cold Room Insulation Datails 7
Figure A-8 Enlarged Cold Room Insulation Datails
Figure A-9 Cold Room Insulation Datails 8
Figure A-10 Cold Room Insulation Detail 9
Figure A-11 Cold Room Insulation Detail 10
Figure A-12 precast Concrete Single Tee Construction
Figure A-13 Typical Underfloor Air Duct Heat System for Slab on Ground Freezers
Figure A-14 Typical Underfloor Air Duct Heat System
Figure A-15 Underfloor Air Duct Heat System Thru Wall Detail
Figure A-16 Underfloor Warming System Detail
Figure A-17 Typical Electric-Resistance Heating System For Slab On Ground Freezers
Figure A-18 Typical Ground Temperature Indicator Installation
Figure A-19 Typical Cold Storage Door With Air Curtain
Figure A-20 Typical Air Curtain Detail At Door Head
Figure A-21 Typical Suspended Ceiling Panel/Wall Panel Construction
Figure A-22 Typical Suspended Ceiling Panel/Wall Panel Construction - 2
Figure A-23 Typical Wall Curb
Figure A-24 Typical Vinyl Moldings For Use On Interior Wall Finishes
Figure A-25 Typical Fastener Detail And Vapor Barrier Penetration At Masonry Wall/Roof Juncture
Figure A-26 Typical Cooler Floor Insulation
Figure A-27 Typical Freezer Floor Insulation
Figure A-28 Typical Exterior Wall Panel/Roof Panel Construction
Figure A-29 Typical Wall Panel Construction - 1
Figure A-30 Typical Wall Panel Construction - 2
Figure A-31 Typical Pre-Fabricated Insulated Building
References - ufc_4_442_01n0156
References - Cont'd - ufc_4_442_01n0157
Naval Facilities Engineering Command (NAVFACENGCOM) Manuals
Naval Facilities Engineering Command (NAVFACENGCOM) Manuals - Cont'd
Naval Supply Systems Command (NAVSUP) Publications - ufc_4_442_01n0160
Instructions - ufc_4_442_01n0162
Standardization Document Improvement Proposal - ufc_4_442_01n0163
Naval Supply Systems Command (NAVSUP) Publications - ufc_4_442_01n0164
Instructions - ufc_4_442_01n0166
Standardization Document Improvement Proposal - ufc_4_442_01n0167