UFC 4-721-10
31 July 2002
4-13
LOCK REQUIREMENTS. Electric locks are required on Apartment
entrance doors and bedroom doors.
Provide each occupant one key that opens the apartment entry
door, and one bedroom door.
Navy projects require electric locks for closet doors; provide each
occupant with a second key for entry to his closet, without access
to the other occupant's closet.
Marine Corps projects require padlocking slide bolt hardware for
closets.
4-14
PARKING. In addition to the parking requirements outlined in
Chapter 10, provide parking for 70% of the resident capacity. Motorcycle parking
should be provided as necessary. Provide dedicated space with concrete
paving. Bicycle parking should be provided as necessary. Provide secure,
weather protected, conveniently located facilities. Provide visitor parking for 2%
of the resident capacity. Locate staff parking at the outer areas of the parking
area.
4-7