UFC 4-721-10
31 July 2002
Natural Gas is prohibited in individual living/sleeping areas.
Provide one Service Sink in service or housekeeping closets at
each floor.
Use the following fixtures as standards:
o Washerless faucets at lavatories.
o Single lever faucets at tub showers or shower stalls.
o Shower units are to use terrazzo base with full height solid
surface material or ceramic surround.
o Shutoff valves for each fixture.
o Tank type, water saver, single piece, elongated bowl water
closets with closed front seat, and lid in private living units.
Areas with low water pressure should use power-flush type water
closets.
o Flow restrictive type showerheads at showers.
o Acid-resisting cast iron bathtubs with metal stopper. Arrange as
tub and shower with full height surround.
Central Heads: For central heads in open-bay designs, provide the
following:
o Water closets: 1 per 10 persons
o Lavatories: 1 per 10 persons
o Showers: 1 per 8 persons
o Water coolers: 1 per 100 persons
Provide one Service Sink in service closets or housekeeping
closets at each floor.
10-44
ELECTRICAL. Base electrical system design calculations on
multi-family occupancy rather than interior corridor occupancy since bachelor
housing is the full-time home of the residents, and therefore has a higher
demand factor. Provide the following as required:
Distribution equipment
Wiring
10-21