UFC 3-530-01
22 August 2006
OFFICES
Waiting Areas
Pendant or surface
mounted luminaires
provide surface brightness
and vertical illuminance.
A
B
Recessed wallwashers or
A
accent lights increase wall
brightness and highlight
features.
Introduce and control
daylight. Integrate with
C
electric lighting system to
reduce energy use.
Task lighting increases the
illuminance on a task,
allowing the ambient light
levels to be lower.
EQUIPMENT RECOMMENDATIONS:
LUMINAIRE
LAMP
CONTROLS
Pendant or surface mounted
Compact fluorescent lamps,
A
decorative luminaire.
3500K color temperature,
or switching.
80 CRI +
Linear fluorescent lamps,
A
fluorescent luminaire.
3500K color temperature,
or switching.
ALT
75+ CRI
Compact fluorescent lamps,
B
downlight/wallwasher.
3500K color temperature,
or switching.
80 CRI +
Linear fluorescent desk task lighting
2', 3', and 4' linear
Manual on / off or local
C
over desks.
fluorescent T8, T5, or T2
occupancy sensor.
lamps 3500K color
temperature, 75 CRI +
CRITICAL DESIGN ISSUES:
waiting areas, the electric lighting can be turned off when there is adequate
light.
Appearance of Space and Luminaires: Because facility visitors often
occupy waiting areas, the aesthetic appearance of the space and the
luminaires is an important criterion.
Target Horizontal Illuminance ( 10%): 100 lux (10 fc) ambient, 500 lux (50
fc) on the task
6-13