UFC 3-535-01
17 November 2005
Drawings:
C-6046, Frangible Coupling Type I and Type IA, Details
D-6076, ALSF-2 Approach Lighting System 6'-0" to 128'-0" Low Impact Resistant (LIR)
Structures
D-6155, ALSF-2, 6' to 128' and MALS, 40' to 128' LIR Structures
Specifications:
C-1391, Installation and Splicing of Underground Cable
E-910, Structural Steel
E-982, PAR 56 Lamp Holder
E-2159, Runway End Identifier Lighting System (REIL)
E-2325, Medium Intensity Approach Light System with Alignment Indicator Lights
E-2491, Approach Light, Semi-flush, Steady Burning
E-2628, Sequenced Flashing Lighting System Elevated and Semi-flush with Dimming
and Monitoring
E-2651, Omni Directional Approach Lighting System (ODALS)
E-2689, Dual Mode High Intensity Approach Lighting System (ALSF-2/SSALR)
E-2702, Low Impact Resistant Structures
E-2756, Four Box PAPI
Miscellaneous:
FAA Engineering Brief No. 53, Land and Hold-Short Lighting Systems
FAA Order 89200.1A, United States Standard Flight Inspection Manual
FAR Part 77, Objects Affecting Navigable Airspace
FAR Part 139, Certification and Operations: Land Airports Serving Certain Air Carriers
Miscellaneous
ANSI A14.3-1984, Fixed Safety Requirements for Ladders
ANSI/EIA-222, Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures
ANSI/IEEE C 37.90.1-1989, Standard Surge Withstand Capability (SWC) Tests for
Protective Relays and Relay Systems
ASTM A-123, Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron
and Steel Products E1-1998
ASTM A-153, Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel
Products E1-1998
ASTM D 4956, Sheeting Retroreflective, for Traffic Control
CAN/CSA C22.2 No. 142, Process Control Equipment
ICAO Annex 14, Chapter 5, Visual Aids for Navigation
IEEE 519-1992, Recommended Practices and Requirements for Harmonic Control in
Electrical Power Systems
ISO 9000, Quality Management and Quality Assurance Standards
NEMA ICS1, Industrial Control and Systems General Requirements
NEMA ICS2, Industrial Control and Systems Controllers, Contractors, and Overload
Relays Rated Not More than 2000 Volts AC or 750 Volts DC
NEMA ICS 3, Industrial Control and Systems Factory Built Assemblies
UL 508, UL Standard for Safety Industrial Control Equipment Seventeenth Edition;
Reprint with Revisions through and including 7/16/99