UFC 4-022-01
25 May 2005
barricades, traffic control devices, access controls, and lighting. Do not locate controls
for other aspects of an installation security system in the gatehouse or other facilities
associated with an ECF. Locate the installation security center or emergency control
center within the controlled perimeter of the installation. The gatehouse should serve
only as the control center for equipment associated with the ECF.
Base the design of the gatehouse on consideration of the following equipment and
functions:
Electronic control panels for all current or anticipated future automated gates,
barriers, or alarms;
Monitor stations for closed circuit television or computer monitors associated
Storage for traffic control devices, weapons, and personnel equipment including
vehicle inspection kits and the storage of personal protective equipment for
CBR exposure;
Computer servers for future automated identification systems;
Counter or work space; and
A unisex restroom.
6-9.3
Sentry/Guard Booth
The sentry/guard booth is located in a median strip or channelization island between
traffic lanes. The booth provides one or two guards with protection against the weather
and potential threats (Securing U.S. Army Site Access Points.) It should have space
allotted for electronic control panels for gate automation equipment, workspace
incorporating space for computer monitors, and an electrical panelboard. It should be
possible to enter or exit the booth from either side of the structure.
6-9.4
Overwatch Position
Many installations desire additional position(s) for security personnel to facilitate a
response to a threat. These positions are normally placed in the response zone to
facilitate surveillance and armed response. This position may be fixed or
temporary/portable. Manning of the overwatch position will be in accordance with the
installation physical security plans. Design the facility to permit security personnel to
respond to any attackers from a protected position (Securing U.S. Army Site Access
Points.) A permanent facility will normally be site-built. The position should be provided
with emergency fast operation (EFO) controls to activate the active vehicle barrier
system. Provide an enunciator in the overwatch position to alert security personnel of
the duress alarm being triggered at the other guard facilities. Maximize visibility from
the facility, with a minimum of 180-degree visibility. The overwatch position should have
a direct line of sight to the access control zone of the ECF including identification and
inspection areas.
The location of the overwatch position should also be designed to afford personnel the
ability to assess the threat, initiate alarms, activate the barrier system (if other personnel
6-26