I
DG 1110-3-106
I. Criteria.
(2) For general guidance on interior design, see DG
Table 4-17 lists outline criteria for designing student
1110-3-122.
lounges.
Table 4-17 Criteria for Student Lounges.
Space Criteria
Area/Person: Seating
30 s.f./person
Standing
6 s.f./person
Ceiling Height
9 ft.
Floor Loading
Reference: TM 5-809-1, Structural Design
Environmental
Thermal
Temperature, maintained operation
Relative humidity
50-60%
Outside air required/person
10 cfm (minimum)
6 per hour (minimum)
Air changes
Air movement, air-conditioned
40 cfm (maximum)
Air pressure, mechanical ventilation
100 cfm (maximum)
Air pressure
Negative
Lighting
General lighting level
30 fc. (maintained)
70, reference: IES Lighting Handbook Applications
Volume
Daylighting
Yes, open view necessary
Location of lounges important to insure no
Service Criteria
Plumbing
Vending machine requirements
Electrical
Power
110 V
4-78