UFC 4-730-10
15 June 2006
FIGURE C-1.1. SAMPLE COMPLETED INTERACTIVE WORKSHEET FOR AN
AIR FORCE FIRE STATION
Sample Air Force Fire Station Project, Brooks AFB, San Antonio, TX
Select Service Branch:
Air Force
Select Type of Facility
Combination
* Select Type as Structural, ARFF, or Combination.
Select Class of Facility
Large HQ
* Select Class as HQ/Main, Satellite, or Large HQ.
Staffed Companies and Dorm Rooms
Enter No. of Structural Companies:
2
Enter No. of ARFF Companies:
3
* Air Force stations range from 1 company up to 8 cos. Dorm Room counts relate to co. count as follows: 5
rooms per structural co. and 4 rooms per ARFF co. You can modify the count below.
Based on no. of companies entered, the following dorm rooms will be provided:
22
Modify Dorm Room count (+ or -) as needed:
* Add or subtract to the Dorm Room count as needed. Note, each Ambulance co.
will typically require +2 rooms and each Rescue co. will typically require +3 rooms.
Also consider X-staffing when modifying the count. Carefully review final room count
Total Dorm Room Count:
22
with PM.
Enter No. of Each Class of Vehicle to be Housed
Bay Sizes **
Large
6706 mm (22 ft.) by 18288 mm (60 ft.)
3
Medium
6706 mm (22 ft.) by 18288 mm (60 ft.)
Large ARFF
6706 mm (22 ft.) by 18288 mm (60 ft.)
1
Medium ARFF
6706 mm (22 ft.) by 18288 mm (60 ft.)
3
Small vehicles do not have a dedicated bay size.
Small
5
** Bay size includes area required around vehicle. Bay sizes are driven by largest
vehicle selected, i.e., if at least 1 Large ARFF truck is entered, all bays will
Total Vehicles:
12
accommodate that size truck. See Para. 2-2.2-1 for more information.
Maintenance and Apparatus Room Spaces
m2
ft.2
Based on vehicle classes & quantities entered above, the basic Apparatus Room is sized:
858.4
9,240
Based on the quantity of Small vehicles entered above, consider additional area as follows:
245.3
2,640
* This suggested area must be carefully reviewed by the planning team. Review the
Check here to delete additional Bay area. >
actual size of Small vehicles and space available in other bays.
Based on no. of Dorm Rooms entered above, the PPE Gear Storage Area is sized:
20.4
220
Based on selections entered above, the Hose Storage Area is sized:
5.0
54
Based on selections entered above, the SCBA Maint. Room is sized:
26.8
288
Based on selections entered above, the SCBA Compressor Rm is sized:
9.3
100
Based on selections entered above, the Work Rm/Equip Maint. is sized:
11.1
120
Based on selections entered above, the Equip Wash/Disinfect. is sized:
13.9
150
C-2