UFC 4-730-10
15 June 2006
FIGURE C-1.4. SAMPLE COMPLETED INTERACTIVE WORKSHEET FOR AN
AIR FORCE FIRE STATION (continued)
Dispatch
m2
ft.2
5
89.2
960
Dispatch includes Dispatch Bathroom at:
48
4.5
Dispatch includes Dispatch Kitchenette at:
20
1.9
Dispatch includes Additional IT Room Space space at:
60
5.6
Select Dispatch Supervisor (yes or no):
Yes
5.9
64
* This provides space for a Dispatch Supervisor's workstation.
Building Totals
Subtotal - Total Net Building Area
27,723
2,575.5
Net-to-Gross factor (modify as necessary):
(factor at 0.19)
19%
5,267
463.6
* The net-to-gross factor accounts for circulation space, mechanical space, and wall thicknesses. The net-to-
gross multiplier for Fire Stations may vary from 18% to 22% depending on the size of the Apparatus Room
relative to the rest of the facility. Typically, the larger the Apparatus Bay, the lower the multiplier and vice versa.
However, carefully consider the entire building configuration before changing the factor from the default setting
of 22%.
TOTAL GROSS BUILDING
Summary for Air Force Fire Station:
32,990
3,039.1
Type of Facility = Combination
Class of Facility = Large HQ
Total Dorm Room Count = 22
Total No. of Apparatus Bays = 9
Site
m2
ft.2
Based on selections entered above, Staff Parking is sized:
1,839.4
19,800
Based on selections entered above, Visitor Parking is sized:
209.0
2,250
Based on selections entered above, Bicycle Rack Area is sized:
14.9
160
Based on selections entered above, Site Approach to Apparatus Bays is sized:
1,672.2
18,000
Based on selections entered above, Agent Storage (ARFF) is sized:
27.9
300
Based on selections entered above, Agent Storage (Structural) is sized:
4.5
48
Based on selections entered above, Patio is sized:
32.5
350
TOTAL GROSS SITE SUPPORT
40,908
3,800.4
TOTAL GROSS FACILITY (BUILDING + SITE SUPPORT)
6,839.4
73,898
C-5