UFC 3-530-01
22 August 2006
Figure 4-4. Diagrams of toplighting strategies.
Vertical glass is shaded by overhang on
south side.
No overhang required on north side.
Reflective roof directs light onto horizontal
surface.
Roof Monitor
Vertical glass is shaded by overhang.
High reflectance surfaces redirect and
diffuse sunlight.
Angled Clerestory
High reflectance surfaces redirect and
diffuse sunlight.
Splay directs light and reduces contrast.
Vertical baffles block direct sunlight.
Horizontal Skylights with Splay
4-7