UFC 3-535-01
17 November 2005
Provide monitoring which, at a minimum, gives a positive indication at a control facility
that power is being provided to the system.
3-2.8
Equipment
See paragraph 13-9.1; fixtures and supports for ALSF-1 apply.
3-2.9
Compliance with International Military Standards
3-2.9.1
ASCC
This standard meets the requirements for a type C system as described in ASCC AIR
STD 90/27.
3-2.9.2
NATO
This standard meets the requirements for a Type II system as described in NATO
STANAG 3316 except for the vertical aiming of the lights.