UFC 4-010-01
8 October 2003
Including change 1, 22 January 2007
D-1.1.3.1
Container Structures and Pre-engineered Buildings. For these
structures, apply the guidance for new and existing buildings in Appendix B.
D-1.1.3.2
Fabric Covered and other Expeditionary or Temporary Structures.
Provide the standoff distance from Table D-1 for the applicable structure category.
D-1.2
Standard 2. Structure Separation. Structure separation requirements
are established to minimize the possibility that an attack on one structure causes
injuries or fatalities in adjacent structures. The separation distance is predicated on the
potential use of indirect fire weapons.
D-1.2.1
Billeting and Primary Gathering Structures.
D-1.2.1.1
Container Structures and Pre-engineered Buildings. For these
structures, ensure that adjacent inhabited structures are separated by at least 10
meters. Where it is necessary to encroach on that separation distance, analyze the
structure and harden structure components as necessary to mitigate the effects of the
explosive indicated in Table D-1 to the appropriate level of protection shown in Table B-
1. Levels of protection are described in Table 2-1 and in UFC 4-020-01.
D-1.2.1.2
Fabric Covered and other Expeditionary or Temporary Structures.
For all new billeting and primary gathering structures, ensure that adjacent structures
are separated by at least the distances in Table D-1. Where it is necessary to encroach
on those structure separations, analyze the structure and provide hardened structure
components as necessary to mitigate the effects of the explosive indicated in Table D-1
to the appropriate level of protection as shown in Table D-1. Levels of protection are
described in Table 2-2 and in UFC 4-020-01.
D-1.2.2
Other Inhabited Structures. There are no minimum separation
distances required for antiterrorism for inhabited structures other than billeting and
primary gathering structures.
Standard 3. Unobstructed Space. Keep areas within 10 meters (33
D-1.3
feet) of all expeditionary and temporary structures free of items other than those that are
part of the utilities and other supporting infrastructure.
D-2
ADDITIONAL STANDARDS. In addition to the specific standards
detailed in this appendix, apply the standards from Appendix B to expeditionary and
temporary structures as follows:
D-2.1
Container Structures and Pre-engineered Buildings. For these
structures, all standards in Appendix B apply.
D-2.2
Fabric Covered and other Expeditionary or Temporary Structures.
Apply the following standards from Appendix B to these structures:
D-2.2.1
Standard 3. Drive-Up/Drop Off Areas.
D-2.2.2
Standard 4. Access Roads.
D-3