MIL-HDBK-1024/1
8.5.2
Location. Locate the air passenger terminal on the apron line as a
stand-alone facility or combined with the air operations building or the air
cargo building. When not combined with air operations building, locate in
reasonable proximity to the air operations building. Refer to par. 2.2.6 and
MIL-HDBK-1021/1.
8.5.3
Architectural and Structural Requirements. See Facility Plate
141-11 (Sheets 1 through 3 of 3). Provide the following:
a)
Baggage conveyors for baggage check-in and claim areas.
b)
Security vault accessed from reserved waiting lounge.
c)
Kitchenette accessed from reserved waiting lounge.
d)
Pay telephone stations and concession areas.
e)
Passenger security screening and baggage x-ray equipment.
f)
A separate holding area for security cleared passengers.
g)
Built-in furnishings including information and check-in
counters.
h)
Space for infant changing area in men's and women's restrooms.
i)
Interior layout and design to provide quiet and active waiting
areas.
j)
Storefront type windows and doors at terminal main entrances.
k)
Public address and passenger paging system.
l)
Facility and restroom areas readily accessible by the physically
handicapped.
Wire Mesh Partitions. Construct wire mesh partition with door for
8.5.3.1
detention area. Refer to NFGS-10605.
8.5.3.2
Ceilings.
Consider an architecturally exposed structural ceiling.
8.5.3.3
Overhead Doors.
Provide electrically operated overhead doors.
8.5.3.4
Windows.
Refer to
par. 2.3.10.
8.5.3.5
Pre-engineered Buildings.
Consider using a pre-engineered metal
building. Refer to NFGS-13121.
160