UFC 4-211-01N
25 October 2004
Including change 1, 1 October 2006
Administrative spaces Resilient tile or carpet as requested by the
activity.
Locker rooms Ceramic tile
Toilets Ceramic tile
Showers Ceramic tile
CO, XO suite Carpet
Officers Ready Room Carpet
Corridors Resilient tile
3-22.6.2
Bases.
Administrative spaces, corridors, and spaces with resilient flooring
or carpet Resilient
Spaces with Ceramic tile walls and floors Ceramic
3-22.6.3
Walls. Paint all walls except for pre-finished materials.
3-22.6.4
Ceilings.
Administrative Spaces, All Spaces on Second floor level
Suspended Acoustical
Showers Suspended gypsum wallboard
Corridors Suspended acoustical panels
Equipment rooms, mechanical rooms Exposed construction,
painted.
3-22.7
Additional Architectural Requirements.
3-22.7.1
Exterior.
3-22.7.2
Restrictions on the Use of Uncoated Aluminum
3-22.7.2.1 Seacoast. Aluminum roofing and siding should not be specified for
structures located within 16 km (10 miles) of the seacoast, due to salt deposition
or incrustation from inshore winds and salt-laden atmosphere.
3-22.7.3
Exterior and Interior. The restrictions for the use of preformed
(corrugated) aluminum roofing and siding are applicable also to sandwich panel