INDIVIDUAL SPACE CRITERIA
DG 1110-3-112 May 1979
4-5 SUPPORT SPACES (cont'd)
e. TOILETS
For sanitary purposes, shared between students and
Use
staff, with separate facilities for men and women.
Separate space is required for lockers and showers in
toilets serving vocational training space.
Varies
Occupant load
For toilets serving academic spaces, assume 25%
Male/Female Ratio
utilization by women and 75% utilization by men
unless local circumstances indicate otherwise. For
toilets, showers and lockers serving vocational train-
ing spaces, assume 10% utilization by women and
90% utilization by men unless local circumstances
indicate otherwise. Base assumptions on peak oc-
cupant loads in the respective areas that the facilities
will support.
1/40 men
Water closets
Fixture allocation
1/25 women
1/40 men
Urinals
1/25 men
Lavatories
1/25 women
1/15 men
Showers
1/15 women
1/man
Lockers
1/woman
30 SF
Water closet compartment
Space Allocation (unit estimates)
50 SF
WC compartment for handicapped
15 SF
Lavatory
15 SF
Urinal
35 SF
Shower compartment
5 SF
Locker tier (2 lockers/tier)
Detailed provisions for handicapped persons shall
conform to current criteria (EM 1110-1-103).
4-41