UFC 3-535-01
17 November 2005
5-3.6
Power Requirement
Provide a main power supply and circuits that permit independent control except on a
taxiway with centerline lighting. In this case, they may be connected to and controlled
with the taxiway centerline lights.
5-3.7
Control Requirement
Provide remote on/off and intensity control. Runway exit lights may be controlled with
associated taxiway centerline lights.
5-3.8
Monitoring Requirements
There are no monitoring requirements.
5-3.9.
Compliance with International Military Standards
5-3.9.1
ASCC
These standards meet AIR STD 90/27.
5-3.9.2
NATO
These standards meet NATO STANAG 3316.
Figure 5-7. Taxiway Short Radius High Speed Exit Lights
7.5M (25FT) TYPICAL
PT
RUNWAY EDGE
7.5M (25FT) TYPICAL
RUNWAY C
L
1M (3FT)
LEGEND
UNI-DIRECTIONAL LIGHTS (STANDARD TAXIWAY CENTERLINE)
MAY BE BI-DIRECTIONAL IF USED FOR BI-DIRECTIONAL TRAFFIC
87