UFC 3-535-01
17 November 2005
Figure 5-5. Taxiway Centerline Lighting Configuration
TAXIWAY CLEARANCE BAR (HOLD POINT)
TAXIWAY CLEARANCE BAR (HOLD POINT)
Y
G
Y
G
1.5M (5FT)
RUNWAY EDGE
C RUNWAY
L
C
L
TAXIWAY
C
L
SEE NOTE 3
TAXIWAY
CLEARANCE BAR
(HOLD POINT)
SEE NOTE 1
C
L
30M MIN.
SEE NOTE 2
(100FT) MIN.
LONGITUDINAL SPACING CRITERIA
CAT. II IFR
ALL OTHER
NOMINAL
15M (50FT)
30M (100FT)
AT INTERSECTIONS (SEE NOTE 2)
15M (50FT)
15M (50FT)
CURVES
RADIUS LESS THAN 120M (400FT)
3.75M (12.5FT)
7.5M (25FT)
(SEE
RADIUS 122M (400FT) TO 360M (1200FT)
7.5M (25FT)
15M (50FT)
NOTE 1) RADIUS GREATER THAN 360M (1200FT)
15M (50FT)
30M (100FT)
NOTES:
1. LOCATE LIGHTS AT PT1 AND PT2, AND SPACE INTERMEDIATE LIGHTS EQUALLY
ALONG SELECTED CURVE IN COMPLIANCE WITH SPACING CRITERIA.
2. SPACE LIGHTS EQUALLY BETWEEN PT1 AND CLEARANCE BAR (HOLD POINT) LIGHTS.
3. RUNWAY AND TAXIWAY EDGE LIGHTS NOT SHOWN.
LEGEND:
Y
BIDIRECTIONAL, GREEN AND YELLOW
G
BIDIRECTIONAL, GREEN
UNIDIRECTIONAL, YELLOW
83