UFC 4-171-05
1 January 2005
with change 25 October 2006
D sample 5034-R Continued
Project Number : 10317
Project Ttle
: AR Center/OMS/AMSA/Unh Strg
Date
: Jun 30, 2005
Functional space Details - Actual/ english
214 - Maintenance - tank and Automotive
STORAGE AREA FOR REFERENCE MANUALS AND DISPATCH OFFICE IS DESIRABLE. THIS
AREA SHOULD BE INCORPORATED AS PART OF THE OMS SHOP OFFICE.
APPROVED SIZE = 11.1 SM (120 SF)
VB1
Shop Office
AMSA, SHOP OFFICE: LOCATE SHOP OFFICE TO PROVIDE MAXIMUM VISIBILITY OF WORK
BAYS. ACCESS SHOULD BE PROVIDED FROM THE SHOP OFFICE INTO THE WORK BAYS
AND EXTERIOR OF THE BUILDING.
A subshop of AMSA 95 is located n Conway. The subshop consists of two mechanics with
administrative duties. Approve one 22.3 SM (240 SF) Shop Office.
VB2
Locker Room
AMSA LOCKER ROOM: 0.93 SM (10 SF) PER RECOGNIZED AMSA PERSON. LOCKER ROOM
FOR FEMALE PERSONNEL WILL BE INCORPORATED INTO THE WOMEN'S TOILET. MINIMUM
AREA WILL BE 9.3 SM (100 SF). Provide wall hung, full size, solid metal lockers, 15 inches wide by
18 inches deep by 72 inches high. Incorporate as part of the OMS Unisex tolet.
LOCKER ROOM AREA = 2 PERSONS X 0.93 SM (10 SF) = 1.86 SM (20 SF) => 9.3 SM (100 SF)
VB3
Class Room/Break Area
AMSA, CLASS ROOM/BREAK AREA: SHARE FACILITIES IN THE MAIN USARC.
VB4
Tool Room
AMSA, TOOL ROOM: Locate adjacent to the supply room with direct accessibility to the work bays.
Divide the space nto 2 separate caged areas with sliding cage doors.
WIRE/EXPANDED METAL STORAGE CAGES 2.4-METER BY 3.7-METER (8 FT X 12 FT) WITH
SLIDING DOORS FOR TOOL AND PARTS STORAGE. CAGES MUST EXTEND TO WITHIN ONE
INCH OF THE FLOOR AND CEILING.
2 Work Bays x 8.9 SM (96 SF) = 17.8 SM (192 SF).
180