UFC 4-171-05
1 January 2005
with change 25 October 2006
D sample 5034-R Continued
Project Number : 10317
Project Ttle
: AR Center/OMS/AMSA/Unh Strg
Date
: Jun 30, 2005
Functional space Details - Actual/ english
214 - Maintenance - tank and Automotive
Shop Office
VA1
OMS, SHOP OFFICE: LOCATE SHOP OFFICE TO PROVIDE MAXIMUM VISIBILITY OF WORK
BAYS. ACCESS SHOULD BE PROVIDED FROM THE SHOP OFFICE INTO THE WORK BAYS
AND EXTERIOR OF THE BUILDING.
5.6 SM (60 SF) PER AUTHORIZED OMS ADMINISTRATIVE PERSON WHO WORKS IN THE OMS
ON THE LARGEST MAINTENANCE DRILL WEEKEND, PLUS 11.1 SM (120 SF) PER FULL-TIME
OMS MAINTENANCE ADMINSTRATIVE PERSON.
1 FULLTIME X 11.1 SM (120 SF) = 11.1 SM (120 SF)
VA2
Tool & Parts Room
OMS, TOOL AND PARTS STORAGE: SUBDIVIDE AREA INTO 2 EQUAL SECTIONS WITH
WIRE/EXPANDED METAL STORAGE CAGES 2.4-METER BY 3.7-METER (8 FT X 12 FT) WITH
SLIDING DOORS FOR TOOL AND PARTS STORAGE. CAGES MUST EXTEND TO WITHIN ONE
INCH OF THE FLOOR AND CEILING. THIS SPACE SHOULD BE ADJACENT TO THE STORAGE
ROOM AND DIRECTLY ACCESSABLE TO THE WORKBAYS.
VA3
Storage Room
OMS, STORAGE ROOM: SUBDIVIDE AREA INTO 2 SECTIONS WITH WIRE/EXPANDED METAL
STORAGE CAGES 2.4-METER BY 3.7-METER (8 FT X 12 FT) WITH SLIDING DOORS FOR
STORAGE. CAGES MUST EXTEND TO WITHIN ONE INCH OF THE FLOOR AND CEILING. THIS
SPACE SHOULD BE ADJACENT TO THE TOOL AND PARTS ROOM AND DIRECTLY
ACCESSABLE TO THE WORKBAYS. AREA TO BE USED FOR STORAGE OF ANCILLARY
EQUIPMENT ISSUED WITH VEHICLES. A MINIMUM OF TWO DUPLEX 110V OUTLETS SHALL
BE PROVIDED PER MODULE.
VA4
Flammable Storage
OMS, FLAMMABLE STORAGE : MUST COMPLY WITH DESIGN GUIDE STANDARDS AND EPA
STANDARDS AS OF DATE OF CONSTRUCTION. DOORS MUST OPEN TO THE OUTSIDE OF
THE BUILDING.
VA6
REF MANUAL STORAGE/DISPATCH OFFICE:
DUE TO THE SIZE AND TYPE OF UNIT AND EQUIPMENT SERVICED OUT OF THIS OMS, A
STORAGE AREA FOR REFERENCE MANUALS AND DISPATCH OFFICE IS DESIRABLE. THIS
AREA SHOULD BE INCORPORATED AS PART OF THE OMS SHOP OFFICE.
179