UFC 4-171-05
1 January 2005
with change 25 October 2006
D sample 5034-R Continued
Project Number : 10317
Project Ttle
: AR Center/OMS/AMSA/Unh Strg
Date
: Jun 30, 2005
Functional space Details - Actual/ english
171 - training Building
A weapons simulator room is authorized based on the Engagement Skills Trainer
(EST) Man Smulaton Unt (MSU) configuration issued to a facility. The EST 5-lane
Trainer is authorized area of 113.8 square meters (1225 square feet).
IH1
Mens Toilets & Showers -
SUPPORT AREA, MEN'S TOILETS AND SHOWERS:
ALLOWANCE IS BASED ON 90% OF THE NUMBER OF PERSONNEL IN
ATTENDANCE DURING THE LARGEST DRILL WEEKEND.
16 SOLDIERS X 90% = 15 MEMBERS
FIRST INCREMENT OF 100
= 32.5 SM (350 SF)
TOTAL SPACE AUTHORIZED FOR MEN'S TOILETS AND SHOWERS = 32.5
SM (350 SF)
THE TOILET AND SHOWER WILL BE DESIGNED AND CONSTRUCTED
HANDICAP ACCESSIBLE.
IH2
Womens Toilets & Showers -
SUPPORT AREA, WOMEN'S TOILETS AND SHOWERS:
ALLOWANCE IS BASED ON 30% OF THE NUMBER OF PERSONNEL IN
ATTENDANCE DURING THE LARGEST DRILL WEEKEND.
16 SOLDIERS X 30% = 5 MEMBERS
FIRST INCREMENT OF 100
= 20.9 SM (225 SF)
TOTAL AUTHORIZED FOR THE WOMEN'S TOILET AND SHOWERS = 20.9 SM
(225 SF)
THE TOILET AND SHOWER WILL BE DESIGNED AND CONSTRUCTED
HANDICAP ACCESSIBLE.
IH3
Locker Room -
SUPPORT AREA, LOCKER ROOM:
PROVIDE LOCKER ROOM FOR THE RESERVE UNITS. THE LOCKER ROOM
SHOULD BE LOCATED ADJACENT TO THE LATRINE FACILITIES.
ALLOWANCE IS BASED ON THE TOTAL AUTHORIZED DRILLING STRENGTH
OF THE LARGEST DRILL WEEKEND.
107 SOLDIERS/10 = 10.7=> 11 X 9.29 SM (100 SF) = 102.2 SM (1100 SF)
IH5
Break Area -
SUPPORT AREA, BREAK ROOM:
175