UFC 4-171-05
1 January 2005
with change 25 October 2006
D sample 5034-R Continued
Project Number : 10317
Project Ttle
: AR Center/OMS/AMSA/Unh Strg
Date
: Jun 30, 2005
Functional space Details - Actual/ english
171 - training Building
ID2
Armorer Work Area -
ARMORER: SHOULD BE PROVIDED WITH ENTRANCE TO VAULT THROUGH
THIS 9.3 SM (100 SF) AREA AND ADJACENT TO STAGING AREA.
IE1
Classrooms -
EDUCATIONAL AREAS, CLASSROOMS:
CLASSROOMS ARE AUTHORIZED BASED ON THE TOTAL AUTHORIZED
DRILLING STRENGTH OF THE LARGEST DRILL WEEKEND.
109 SOLDIERS/50 = 2.18 -> 3.0 X 27.9 SM (300 SF) = 83.7 SM (900 SF) IS
AUTHORIZED FOR CLASSROOMS.
PROVIDE ONE 83.7 SM (900 SF) CLASSROOM WITH MOVEABLE PARTITION
TO SUBDIVIDE THE CLASSROOM INTO THREE 300 SF CLASSROOMS FOR
SMALLER GROUPS. PROVIDE HALLWAY ACCESS TO ALL CLASSROOMS.
LOCATE THE CLASSROOMS NEAR AN OUTSIDE ENTRANCE FOR EASY ACCESS
WITHOUT GOING THROUGH THE ADMINISTRATIVE AREA.
IE2
Library Readng Room -
EDUCATIONAL AREAS, LIBRARY READING ROOM:
ALLOWANCE IS BASED ON THE TOTAL AUTHORIZED DRILLING STRENGTH
OF THE LARGEST DRILL WEEKEND.
THE MINIMUM AUTHORIZED SPACE IS 27.9 SM (300 SF).
THE LIBRARY READING ROOM SHALL BE DESIGNED TO ACCOMMODATE
READING/STUDY OR CLASSROOM/CONFERENCE ACTIVITIES. LAYOUT OF
THE LIBRARY READING ROOM, LEARNING CENTER, AND LIBRARY
STORAGE/REFERENCE ROOM SHALL BE SIMILAR TO THAT SHOWN ON PAGE
35 OF THE DESIGN GUIDE FOR U.S. ARMY RESERVE FACILITIES. LOCATE
ADJACENT TO THE LIBRARY STORAGE, LEARNING CENTER, AND TRAINING
AID STORAGE AREAS.
IE3
Library Storage -
EDUCATIONAL AREAS, LIBRARY STORAGE:
ALLOWANCE IS 10% OF TOTAL CLASSROOM SPACE.
83.6 SM (900 SF) X 10% = 8.4 SM (90 SF)
PROVIDE SHELVING TO STORE BOOKS, MANUALS, VIDEO TAPES, AND
EIGHT-INCH TECH TAPES IN THE LIBRARY STORAGE ROOM. LOCATE
ADJACENT TO THE LEARNING CENTER, LIBRARY READING ROOM, AND
TRAINING AID STORAGE AREAS.
172