UFC 4-214-02, 24 Jul 03
steel fixtures shall comply with ANSI A112.19.4.
8-4.2
Exposed traps shall be chromium-plated, adjustable-bent tube, 20-gauge brass.
Concealed traps may be plastic (ABS).
8-4.3
Faucets shall be single-control type, with seals and seats combined in one
replaceable cartridge designed to be interchangeable among lavatories, bathtubs and kitchen
sinks, or having replaceable seals and seats removable either as a seat insert or as a part of a
replaceable valve unit. Water flow shall be no more than .158 L/s from any faucet.
8-4.4
Showers shall be equipped with a combination valve and flow control device to limit
the flow to 0.158 L/s at pressures between 137.9 to 413.7 kPa.
8-4.5
Piping shall be concealed. Individual shutoff or stop valves shall be provided on
water supply lines to all plumbing fixtures except showers. Shutoff valves shall be provided for
each bathroom group. In two story buildings, provide separate shutoff valve for each floor.
8-4.6
Water closets. Water closets shall have regular bowl, close coupled siphon jet, floor
outlet with wax gasket, closed-front seat and cover, and an anti-siphon float valve. Water
consumption shall be no more than 6 L per complete flushing cycle. Water closet trim shall
conform to ANSI A112.19.5, Trim for Water-Closet Bowls, Tanks, and Urinals (Dimensional
Standards). Shall be flush valve type for floor or wall mounted, water saver type and shall meet
the requirements of the code.
8-4.7
Urinals. [Shall be flush valve, wall mounted type and shall meet the requirements of
the code.] [Urinals shall be wall mounted, waterless type and shall meet the requirements of the
code.]
8-4.8
Lavatories. Lavatories shall be rectangular counter top type, minimum 508 by 457
mm in size or oval minimum 480 by 410 mm in size. Lavatories shall be vitreous china, cast
iron rimless type (without rings), or cross-link acrylic molded counter top with integral bowl.
Lavatories shall have pop-up drains. Shall meet the requirements of the code.
8-4.9
Showers. Shower stalls shall be of ceramic tile, floor to ceiling, over membrane
waterproofing on a cementitious substrate [; or gel-coated, glass-fiber reinforced polyester.]
[Shower receptors shall be slip resistant cast stone or gel-coated, glass-fiber-reinforced
polyester.] [Shower stall wainscots shall be ceramic tile or gel-coated, glass-fiber-reinforced
polyester.] [Edit as applicable].
8-4.10
Service sinks. Shall meet the requirements of the code.
8-4.11
Electric water cooler. Units shall be electric refrigerated type and shall conform to the
requirements of ARI 1010 and the Lead Contamination Control Act of 1988.
8-4.12
Emergency eyewash/shower and emergency eyewash units. Shall meet the
requirements of the code. Provide as indicated in Chapter 2 Functional and Area Requirements.
8-5
PIPING SYSTEMS. Piping shall be concealed. Individual shutoff or stop valves shall
be provided on water supply lines to all plumbing fixtures except bathtubs and showers. Shutoff
valves shall be provided for each bathroom group. In two story buildings, provide separate
shutoff valves for each floor. Provide cathodic protection and pipe joint bonding systems as
SOW-77