UFC 4-730-01
7 April 2006
including change 1, 20 June 2006
2
The additional file area may be centralized, accommodated in the individual offices, or some
combination of the two.
C-3
MEDIUM ARMY FSC. Table C-1.2 illustrates the complete space program
for medium Army FSC facilities, including all Army FSC required and optional components.
TABLE C-1.2. MEDIUM SPACE PROGRAM FOR COMPLETE ARMY FSC
Space Allocation Standard
Medium
0.0929
Functional Component
2
ft.2
m2
ft.2
Standard
No.
m
Lobby (incl. security desk)
11.15
120 per lobby
2
22.30
240
Lobby Waiting
2.23
24
per person
12
26.76
288
Class Room
27.87
300 per 15 seats
8
222.96
2400
Reception I&R Specialist
7.43
80
per office
2
14.86
160
1
7.43
80
per room
4
29.73
320
Interview Room
Director Office
13.01
140 per office
1
13.01
140
Administrative Assistant
7.43
80
per office
1
7.43
80
Director's copy and support
1.86
20
per room
1
1.86
20
Other Staff Offices
7.43
80
per office
2
14.86
160
Copy/Graphics
5.95
64
per room
3
17.84
192
Storage
3.90
42
per storage room
3
11.71
126
Secure Storage
2.97
32
per storage room
2
5.95
64
Computer Resource + Display
4.65
50
per person
12
55.74
600
ERP
13.01
140 per office
2
26.01
280
RRP
10.03
108 per office
2
20.07
216
Lending Locker/Cleaning Area
15.61
168 per room
3
46.82
504
FRP
13.01
140 per office
2
26.01
280
Volunteer Office
7.43
80
per office
2
14.86
160
AVC
7.43
80
per office
1
7.43
80
Toilets
3.34
36
per fixture
8
26.76
288
Janitor's Closet
1.49
16
per closet
1
1.49
16
Kitchen/Teaching Kitchen
8.92
96
per kitchen unit
2
17.84
192
Break Room
5.95
64
per break room
4
23.78
256
EFMP Office
13.01
140 per office
2
26.01
280
2
1.67
18
per room
2
3.34
36
Additional EFMP File Area
EFMP Common Area
7.43
80
per office
1
7.43
80
Army Emergency Relief
13.01
140 per office
2
26.01
280
AFTB/AFAP
13.01
140 per office
2
26.01
280
Deployment/MOB/SSO
27.87
300 per office
1
27.87
300
NPS
10.03
108 per office
1
10.03
108
FAP Office
13.01
140 per office
2
26.01
280
2
1.67
18
per room
3
5.02
54
Additional Counseling File Area
Group Treatment Room
22.30
240 per group of 8
1
22.30
240
Decompression/Waiting Room
7.43
80
per room
1
7.43
80
SUBTOTAL Required Army FSC Building Net Area
843.53
9,080
Circulation and Mechanical Building Factor @
20%
168.71
1,816
SUBTOTAL Required Army FSC Building Gross Area
1,012.24
10,896
Lobby Child Play Area
4.01
43
per play unit
2
8.03
86
Vending (staff and public)
1.86
20
per machine
6
11.15
120
RSO Office
7.43
80
per office
1
7.43
80
3.25
35
30
97.55
1050
Short-term Alternative Child Care (STACC)
per child (25% of capacity)
CRC Meeting Room
2.68
29
per person
18
48.16
518
* Optional spaces include 20% building factor
24
Estimated Staffing (note, final facility staffing may vary):
C-3