UFC 4-730-01
7 April 2006
including change 1, 20 June 2006
C-7
NAVY-ONLY FSC COMPONENTS. Table C-3 illustrates the space
program for the Navy-only FSC components. These components are spaces that are
specific to the Navy or have Navy-specific size criteria. Use this table in conjunction with
Table C-2 (unified table) that illustrates the space criteria that are common to both the
Navy and Marine Corps.
TABLE C-3. SPACE PROGRAM FOR NAVY-ONLY FSC COMPONENTS
0.0929
Space Allocation Standard
Small
Medium
Large
Extra Large
m2
ft.2
m2
2
m2
ft.2
m2
2
m2
ft.2
Functional Component
Standard
No.
No.
No.
No.
ft.
ft.
Staff Break/Conference Room
7.43
80
per break room
1
7.43
80
2
14.86
160
4
29.73
320
6
44.59
480
Chief of Programs workstation
5.95
64
per workstation
1
5.95
64
1
5.95
64
1
5.95
64
1
5.95
64
RUS
5.95
64
per workstation
1
5.95
64
2
11.89
128
3
17.84
192
4
23.78
256
NPS ("kid friendly")
13.01
140 per workstation
0
0.00
0
1
13.01
140
2
26.01
280
3
39.02
420
Clinical Counseling Office
13.01
140 per office
2
26.01
280 10
130.06
1400
16
208.10
2240 20
260.12
2800
1
1.67
18
per room
1
1.67
18
2
3.34
36
3
5.02
54
6
10.03
108
Additional Counseling File Area
Group Treatment Room
22.30
240 per room (grp of 8)
0
0.00
0
1
22.30
240
1
22.30
240
2
44.59
480
Decompression/Waiting Room
7.43
80
per room
0
0.00
0
0
0.00
0
1
7.43
80
2
14.86
160
FAP Office
13.01
140 per office
1
13.01
140
1
13.01
140
2
26.01
280
4
52.02
560
CRC Meeting Room
2.23
24
per person
10
22.30
240 14
31.21
336
18
40.13
432 24
53.51
576
SAVI
5.95
64
per workstation
0
0.00
0
1
5.95
64
1
5.95
64
2
11.89
128
SUBTOTAL - NAVY REQUIRED NET SPACES
82
886
252
2,708
394
4,246
560
6,032
Circulation and Mechanical Building Factor @
20%
16.46
177 20%
50.31
542
20%
78.89
849 20%
112.07
1,206
SUBTOTAL - NAVY REQUIRED GROSS SPACES
98.77
1,063
301.89
3,250
473.34
5,095
672.45
7,238
SUBTOTAL NAVY FSC (Unified FSC Subtotal + Navy Required Subtotal)
336
3,619
707
7,613
1,229
13,224
1,861
20,038
Child Play Area
4.01
43
per play unit
1
4.01
43.2
1
4.01
43.2
2
8.03
86.4
2
8.03
86.4
RAO
8.92
96
per office
1
8.92
96
1
8.92
96
1
8.92
96
2
17.84
192
Shower/changing/locker
6.69
72
per ADA shower/cha
1
6.69
72
1
6.69
72
2
13.38
144
3
20.07
216
* Optional spaces include 20% building factor
TOTAL NAVY FSC (Add Subtotal Navy FSC + Selected Options)
1
additional file area may be centralized, accommodated in the individual offices, or some combination of the two.
Estimated Staffing (note, final facility staffing may vary):
6
17
26
36
C-7