TABLE 4-28.0. RECREATION ROOM
If required by the Installation mission, this room provides space for the firefighters to engage in
Description/
noisier recreational activities, such as table games (e.g., pool or table tennis) or video games
Usage
and is in addition to the Day Room. Provide some acoustical separation from the Day Room
and the Dorm Rooms.
2.4 m (8 ft.) minimum.
Min. Ceiling Ht.
Walls. Provide a low-maintenance, durable finish such as industrial egg-shell latex paint.
Floor. Provide low-maintenance sheet or tile vinyl flooring material with rubber base.
Consider providing durable commercial carpeting.
Ceiling. Provide acoustical ACP or gypsum board ceiling such as industrial egg-shell latex
paint for gypsum board ceiling.
None required.
Plumbing
20 C (68 F) minimum, 26 C (78 F) maximum. Consider providing a separate thermostat for
HVAC
this space.
Provide Fire Protection System per Paragraph 3-6.3.
Fire Protection
Provide outlets per code. Provide power required to accommodate any game equipment.
Power
540 Lux (50 ft. candles). Provide incandescent energy efficient light fixtures. Consider
Lighting
residential-style lighting fixtures. Consider providing dimmer for all light fixtures.
CCTV. None required.
Communication
CATV/Internal Video. Provide at least one outlet. Consider height of outlet for a wall-
mounted television.
PA/Audio. Provide a speaker.
Telephone. Provide one line with internal two-way communication.
Data. None required.
Security. None required.
None required.
Casework
Provide pool table/table-tennis table, lounge chairs, side tables, bar stools, book cases, and
Furnishings
storage cabinets.
Fixtures &
Equipment
(FF&E)
Provide an STC rating of 50 to 55.
Special
Requirements
4-33