UFC 4-740-03
1 NOVEMBER 2002
TABLE 3-2. ENTRANCE LOBBY
This area will serve as the primary entry for the facility and have some space for
Description/
seating. An air lock is also recommended.
Usage
2.74 m (9 ft.)
Min. Ceiling Ht.
Walls. Paint w/ eggshell sheen on gypsum wallboard. Limited use of special material
finishes such as wood, fabric, or stone.
Floor. Stained concrete or vinyl tile.
Ceiling. Lay-in acoustical panel. Limited use of gypsum wallboard.
One electric water cooler.
Plumbing
20 C (68 F) minimum, 26 C (78 F) maximum.
HVAC
Building system.
Fire Protection
Provide outlets per code and for water cooler.
Power
540 Lux (50 ft. candles).
Lighting
CCTV. 1 outlet for camera.
Communication
CATV/Internal Video. None required.
PA/Audio. Provide one speaker.
Telephone. Provide one line for pay phone.
Data. None required.
Security. None required.
None required.
Casework
Bench seating.
Furnishings
Fixtures &
Equipment
(FF&E)
Provide a door counter on each patron entrance.
Special
Requirements
When designing an OCOR, approximately 2% of the additional OCOR area (as
calculated per Section 2-1.2.3) should be applied to this space.
3-3