Design Guide: Recreation Centers Individual Space Criteria January 1976
stool, typewriter stand.
an adding machine, and
display equipment,
typewriter stand.
(c) Finish Suggestions
A lounge area adjacent to the administrative
Walls
painted drywall
counter is required in the ITT office, which
Floors
carpet
should be open to the transitional area and will
acoustical tile
Ceiling
accommodate the following: kiosks, literature
(d) Colors
racks, poster displays, and serve as a waiting
area for patrons seeking the services of ITT
Walls
staff.
Accents
white, black or charcoal
All ITT areas should be planned to allow casual
requiring verbal contact with a staff member.
(6) Technical Requirements
30 ftc, counter; 10 ftc,
Level
lounge
incandescent task
Type
local, switch behind counter
Control
(b) Power
1 every 12'
Outlets
1 per kiosk
Special
(c) H V A C
78DB; 65WB; RH 50%
Summer
Winter
68
Air changes 10 per hour
P/A
1 station in lounge
Phones
desk set 1 class "A" line
1 speaker station in lounge
Sound
PNC 30-40
Noise criteria
42 dB
Sound level
Ave coef of absorption 0.30-0.40
+40 d B
Transmission (STC)
(7) Interior Requirements
(a) Equipment
2 securable file cabinets; safe, securable
storage of audio-visual display equip-
ment including rear projection slide
viewers and screens; adding machines.
Provisions for teletype may be required,
(b) Furniture
Lounge chairs, stools behind counter,
built-in counter, desk and chair, counter
4-39