UFC 4-010-01
8 October 2003
Including change 1, 22 January 2007
a controlled perimeter, the standoff distances and explosive weight associated with
parking and roadways in Table B-1 apply. If there is no controlled perimeter, assume
that the larger explosive weights upon which the controlled perimeter standoff distances
are based (explosive weight I from Table B-1) can access parking and roadways near
buildings. Therefore, where there is no controlled perimeter, use standoff distances
from parking and roadways according to the distances and the explosive weight
associated with controlled perimeters in Table B-1. Measure the standoff distance from
the closest edge of parking areas and roadways to the closest point on the building
exterior or inhabited portion of the building. In addition, the following apply:
Table B-1 Standoff Distances
for New and Existing Buildings
Standoff Distance Requirements
Location
Building Category
Minimum
Applicable Conventional
Applicable
Standoff
Level of
Construction
Explosive
(1)
Distance
Protection
Standoff
Weight
(2)
Distance
Billeting and High
45 m (3)
25 m (3)
Controlled
I
Occupancy Family
Low
(148 ft.)
(82 ft.)
Perimeter
Housing
or
45 m (3) (4)
25 m (3) (4)
Parking and
Primary Gathering
I
Low
Building
(148 ft.)
(82 ft.)
Roadways
without a
Controlled
25 m (3)
10 m (3)
I
Inhabited Building
Very Low
Perimeter
(82 ft.)
(33 ft.)
Billeting and High
25 m (3)
10 m (3)
Parking and
Occupancy Family
Low
II
(82 ft.)
(33 ft.)
Roadways
Housing
within a
25 m (3) (4)
10 m (3) (4)
Primary Gathering
Low
Controlled
II
Building
(82 ft.)
(33 ft.)
Perimeter
10 m (3)
10 m (3)
Inhabited Building
Very Low
II
(33 ft.)
(33 ft.)
Billeting and High
25 m
10 m
Low
Trash
Occupancy Family
II
(82 ft.)
(33 ft.)
Containers
Housing
Primary Gathering
25 m
10 m
Low
II
Building
(82 ft.)
(33 ft.)
10 m
10 m
Inhabited Building
Very Low
II
(33 ft.)
(33 ft.)
(1) Even with analysis, standoff distances less than those in this column are not allowed for new buildings, but are
allowed for existing buildings if constructed/retrofitted to provide the required level of protection at the reduced standoff
distance.
(2) See UFC 4-010-02, for the specific explosive weights (kg/pounds of TNT) associated with designations I and II.
UFC 4-010-02 is For Official Use Only (FOUO)
(3) For existing buildings, see paragraph B-1.1.2.2 for additional options.
(4) For existing family housing, see paragraph B-1.1.2.2.3 for additional options.
B-2