DG 1110-3-106
c. Mobility and Interchangeability.
B. Site Design Information.
Most interior furnishings should not be of a scale
An activity layout plan should be provided to show
which would require more than two persons to
the operational aspects of using the site, along with a
relocate them, or be so complicated as to require an
discussion of the parking and traffic loads (with
undue amount of time to assemble or disassemble.
notation concerning sources and dates of traffic studies
Whenever possible, care should be taken to choose
conducted), intended procedures for snow and trash
multi-purpose furnishings aesthetically suitable for a
removal, grounds control and security operations, and
variety of needs and activities. Stackable and foldable
provisions for future expansion of parking, buildings,
furniture should be considered for reducing bulkiness
utilities, streets, etc. Aspects of planting care with a
in storage and transport where such requirements exist.
program for feeding and maintenance is also
recommended.
(3) Drawings and Schedules.
Furnishing layouts and schedules must indicate items
C. Building Design Information.
This should include an activity layout plan along with
which are part of the building and items which must
a discussion of methods for altering partition systems
be procured under separate contract. Drawings and
and environmental systems, restrictions and
schedules must be in formats that can be readily
maintenance required by fire safety regulations,
understood by installation personnel who are
intended levels of operation and control of
responsible for procurement and component placement
environmental systems, necessary security and safety
and utilization after delivery. Display sheets consisting
procedures, and aspects of housekeeping and
of placement plans, catalog illustrations, material/color
maintenance. Fire safety plans and protective
construction plans should also be provided along with
together with procurement lists, source data and cost
estimates should be developed as appropriate to
a description and/or plan of features for the physically
accomplish this objective.
handicapped.
2-5 Provision of User Information
D. Technical Information.
All technical information available from manufacturers
of the materials, equipment and accessories
A. Requisites.
The completion records required upon completion of a
incorporated in the facility, will be provided to
facilitate successful maintenance and operation of the
building project are delineated in AR 415-10.
facility. Similar information on special equipment and
Additional requirements for user information are
furnishings should also be provided.
established in ER 1110-345-700, Design Analysis. The
user information supplement to the completion records
must include information on how to best utilize the
facility design. Information must be presented in a
form that facilitates understanding and use by using
service personnel and Facilities Engineer personnel.
2-21