Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-4.3.2.1 Function: Private office for use by S-2 personnel.
2-4.3.2.2 Adjacency requirements: Adjacent to S-2 Clerical /Central Files.
2-4.3.2.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair, and one desk chair. If systems furniture panels are provided in lieu of drywall
partitions, provide workstation type ___.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.3.2.5 Other requirements: Exterior window is desirable. If drywall partitions are used,
provide 914 mm [3'-0"] wide door into each room; door shall have entry function (F81) lockset.
Drywall partitions shall have minimum STC rating of 49.
S-2 Clerical/Central Files. Provide one; 76.2 m2 [820 sf]. S-2 Clerical/Central Files
2-4.3.3
shall be accessed from the lobby or corridor. The area shall have direct access to S-2 private
offices, and the Secured Documents Vault. Occupants: 8 staff , and occasional visitors.
2-4.3.3.1 Function: Open office area for S-2 admin staff; access to other S-2 spaces.
2-4.3.3.2 Adjacency requirements: Adjacent to lobby or corridor. Adjacent to S-2 private
offices and Secured Documents Vault.
2-4.3.3.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate eight
type [___] systems furniture workstations.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.3.3.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Exterior window is desirable. Partitions shall have minimum STC
rating of 49. Minimum ceiling height 2642 mm [8'-8"].
Secured Documents Vault. Provide one room; 13 m2 [140 sf]. Vault shall be
2-4.3.4
certified for open storage of secret material. Class M Modular construction is acceptable.
Provide Class 5 vault door with day gate [verify all vault criteria with user]. To allow future
flexibility in reconfiguring offices areas, locate vault on the perimeter of the administrative areas.
Occupants: 1.
2-4.3.4.1 Function: Storage of documents classified `secret' and below. Workspace for one
clerk.
SOW-45