Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
provide 914 mm [3'-0"] wide door into each room; door shall have entry function (F81) lockset.
Drywall partitions shall have minimum STC rating of 49.
S-4 Clerical/Central Files. Provide one; 76.2 m2 [820 sf]. S-4 Clerical/Central Files
2-4.6.3
shall be accessed from the lobby or corridor. The area shall have direct access to S-4 private
offices. Occupants: 8 staff , and occasional visitors.
2-4.6.3.1 Function: Open office area for S-4 admin staff; access to S-4 offices.
2-4.6.3.2 Adjacency requirements: Adjacent to lobby or corridor. Adjacent to S-4 private
offices.
2-4.6.3.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate eight
type [___] systems furniture workstations.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.6.3.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Exterior window is desirable. Partitions shall have minimum STC
rating of 49. Minimum ceiling height 2642 mm [8'-8"].
2-4.6.4
S-4 Storage & Supplies. Provide one; 24.2 m2 [260sf] of general storage space.
Room shall be under control of, and accessed from, S-4/Clerical/Central Files area. Room shall
be located on exterior wall, with exterior doors leading to paved sidewalk [add requirement for
vehicle access if necessary]. .
2-4.6.4.1 Function: Storage of [identify type of items to be stored] for S-4 Section.
2-4.6.4.2 Adjacency requirements: Adjacent to S-4 Clerical/Central Files and building exterior.
2-4.6.4.3 Furnishings/Fixtures/Equipment: [insert shelving requirement].
2-4.6.4.4 Finishes: Floor: sealed concrete
Base: resilient cove base
Walls: painted gypsum wallboard or painted veneer plaster, or painted concrete masonry units
Ceiling: suspended acoustical panel ceiling
2-4.6.5
Other requirements: Provide 914 mm [3'-0"] wide door into room from
S-4/Clerical/Central Files; provide pair of 914 mm [3'-0"] wide outswinging hollow metal exterior
doors. Doors shall have storeroom function (F86) locksets; exterior doors shall have hold open
devices and auxiliary deadlocks (thumb turn inside, keyed cylinder outside). Provide minimum
2438 mm [8'-0"] wide exterior sidewalk between exterior doors and the main sidewalk leading to
main entry area [modify if paved vehicle loading area is required].
2-4.7
Personnel Administration Center (PAC) Section. Provide one group of offices. In
a two-story building locate PAC Section on the first floor. Locate PAC Section adjacent to S-4
Section.
SOW-49