S-1 Clerical/Central Files. Provide one; 62.3 m2 [670 sf]. S-1 Clerical/Central Files
2-4.2.2
shall be accessed from the lobby or corridor. The area shall have direct access to S-1 and
Command Section private offices, and reception area. Occupants: 7 staff and occasional
visitors.
2-4.2.2.1 Function: Open office area for S-1 admin staff; access to S-1 and Command offices.
2-4.2.2.2 Adjacency requirements: Adjacent to lobby or corridor. Adjacent to S-1 and
Command private offices. Adjacent (and open to) reception area.
2-4.2.2.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate seven
type [___] systems furniture workstations.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.2.2.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Exterior window is desirable. Partitions shall have minimum STC
rating of 49. Minimum ceiling height 2642 mm [8'-8"].
2-4.3
S-2 Section. Provide one group of offices. In a two-story building locate S-2
Section on the second floor. Locate S-2 Section adjacent to S-1 and/or S-3 Sections.
S-2 Officer. Provide one; 8.8 m2 [95 sf]. Room shall be accessed through the S-2
2-4.3.1
Clerical/Central Files area. Occupants: 1, and occasional visitors.
2-4.3.1.1 Function: Private office for S-2 officer.
2-4.3.1.2 Adjacency requirements: Adjacent to S-2 Clerical /Central Files.
2-4.3.1.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair, and one desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.3.1.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Room shall have exterior window. Partitions shall have minimum
STC rating of 55.
Office. Provide two; each 8.8 m2 [95 sf]. Area may be a private office or a systems
2-4.3.2
furniture workstation accessed through the S-4 Clerical/Central Files area. Occupants: 1 in
each office [verify with user].
SOW-44