Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.1.2.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Room shall have exterior window. Partitions shall have minimum
STC rating of 55.
Reception Area. Provide one; 13.9 m2 [150 sf], to accommodate reception desk
2-4.1.4
and waiting area. Reception area shall be accessed through S-1 Clerical/Central Files.
Occupants: 1, and space for four visitors.
2-4.1.4.1 Function: Receptionist workstation and waiting area for visitors to the CO, XO, CSM
offices.
2-4.1.4.2 Adjacency requirements: Adjacent (and open to) S-1 Clerical /Central Files area.
Adjacent to command section toilet, coffee area, CO, XO and Command Sergeant Major offices.
2-4.1.4.3 Furnishings/Fixtures/Equipment: Provide and design area to accommodate one
reception desk (systems furniture workstation type [___]), four side chairs and one magazine
table.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.1.4.5 Other requirements:
2-4.1.5
Command Section Toilet. Provide one private toilet room. Room shall be sized to
comply with handicap accessibility requirements. Room shall be accessed from reception area
2-4.1.5.1 Function: single-occupant toilet and lavatory, for use by command staff and visitors.
2-4.1.5.2 Adjacency requirements: Adjacent to reception area. Near CO, XO, and CSM offices.
2-4.1.5.3 Furnishings/Fixtures/Equipment (FFE): Provide one floor mounted toilet, one wall-
hung lavatory, mirror with shelf above lavatory, Paper towel dispenser/waste receptacle, soap
dispenser, toilet tissue dispenser, and wall mounted grab bars at toilet.
Floor: porcelain tile, or ceramic tile.
Base: porcelain tile, or ceramic tile.
Walls: ceramic tile
Ceiling: painted gypsum wallboard, painted veneer plaster, or painted Portland cement plaster.
2-4.1.5.5 Other requirements: Door shall have privacy function (F76) lockset. Arrange space
so that door does not open directly into reception area. Partitions shall have minimum STC
SOW-42