Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
applicable codes.
5-6.3.1
Penetrations. Penetrations shall be minimized. All openings or penetrations in
Vault floor, walls or ceiling greater than .062 m2 [96 square inches] shall be protected with
welded steel rod-and-bar grid weighing 39.6 kg/m2 [8.1 lb./sf], consisting of 25.4 mm x 4.8 mm
[1" x 3/16"] vertical bearing bars at 25 mm [1"] on center, and 8 mm [5/16"] diameter horizontal
rods at 50 mm [2"] on center; or equivalent protection.
5-6.4
Floor Anchors for GFGI Security Safes.
Provide 10 mm
[3/8"] diameter stainless
steel bar bent into U-shape (25 mm inside radius) with 2" long 90 degree returns at ends of
vertical legs. Overall height shall be 127 mm [5"]; embed 76 mm [3"] of vertical legs (open end)
in concrete floor slab; 51 mm [2"] of U-shaped end will protrude above slab to provide
anchorage for GFGI security safe.
SOW-114