Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
coated. Frames in masonry shall have bituminous back-coating, plaster guards, and shall be
grouted solid.
5-5.5.3
Hollow Metal Frames. Comply with ANSI A250.8/SDI 100. Frames shall be Level
2, 16 gauge, with continuously welded corners and seamless face joints; factory primed.
Anchors and accessories shall be zinc coated. Frames in masonry shall have bituminous back-
coating, plaster guards, and shall be grouted solid.
5-5.5.4
Fire-rated and Smoke Control Doors and Frames. Comply with International
Building Code (IBC), NFPA 80, and requirements of labeling authority. Doors and frames shall
bear labels from IBC approved testing laboratory. Comply with positive pressure testing
requirements of IBC.
5-5.5.5
Interior Door Finish Hardware.
5-5.5.5.1 Hinges. ANSI/BHMA A156.1; template, full mortise; heavy duty, ball bearing on
doors with closers; standard duty anti-friction bearing on doors without closers. Minimum size
4 " x 4 ".
5-5.5.5.2 Locksets on Living Unit Entry Doors. ANSI/BHMA A156.13; mortise lockset with
removable core; non-ferrous base metal.
5-5.5.5.3 Locksets on Interior Doors. ANSI/BHMA A156.2; series 4000, Grade 1, non-
ferrous base metal, removable core.
5-5.5.5.4 Exit (Panic) Devices. ANSI/BHMA 156.3; heavy-duty touch-pad type, through-
bolted mounting. Listed and labeled for panic protection based on UL 305.
5-5.5.5.5 Closers. ANSI/BHMA A156.4; series C02000, Grade 1, hydraulic, factory-sized,
adjustable to meet field conditions. Provide for all entry doors to living units, all doors opening
to corridors and as required by codes.
5-5.5.5.6 Auxiliary Hardware. ANSI/BHMA A156.16. Provide wall or floor stops for all doors
that do not have overhead holder/stops. Provide other hardware as necessary for a complete
installation.
5-5.5.5.7 Kick Plates. ANSI/BHMA A156.6; non-ferrous metal. Provide at all doors with
closers.
5-5.6
Limitations on Use, Classification, and Flame Spread and Smoke Developed
Ratings of Interior Finishes.
Refer to
paragraph 12-6.2.
5-5.7
Casework.
5-5.7.1
Service Areas in Living Units and Coffee Areas in Admin Areas. Provide
manufactured unitized kitchen; or provide architectural cabinets complying with AWI Quality
Standards, Section 400, Custom Grade cabinets with high pressure decorative laminate finish,
meeting NEMA LD3 standards. Horizontal laminate: nominal .050" thick; vertical laminate:
nominal .028" thick. Door and drawer edges shall be heavy duty 3 mm extruded polyvinyl
chloride with self-locking serrated tongue. Countertop shall be post-formed high pressure
decorative laminate with waterfall front edge and integral coved backsplash, or solid surfacing
SOW-111