Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
5-4.10
Exterior Noise Control. [Add requirements for insulation of exterior walls and
roof/ceiling assemblies for attenuation of external noise sources such as airfields].
5-5
INTERIOR DESIGN.
5-5.1
Floors. Comply with requirements of applicable codes. Non-combustible
construction is preferable, even where combustible materials are allowed by code. Floor finish
materials shall be as specified in functional and area requirements listed in Chapter 2 of the
Statement of Work.
5-5.2
Ceramic Tile. Comply with ANSI A 137.1 and the recommendations of Tile Council
of America (TCA) Handbook For Ceramic Tile Installation. Provide marble threshold under
doors where a ceramic tile floor meets a different floor finish.
5-5.3
Interior Walls and Partitions. Comply with requirements of applicable codes. Non-
combustible construction is preferable, even where combustible materials are allowed by code.
Wall finish materials shall be as specified in functional and area requirements listed in Chapter 2
of the Statement of Work
5-5.3.1
Metal Support Systems. Non-load bearing metal studs and furring shall comply
with ASTM C 645; stud gauge shall be as required by height and loading, but shall not be less
than 25 gauge. Maximum stud spacing: 406 mm [16"] on center. Provide galvanized finish.
5-5.3.2
Gypsum Board. Comply with ASTM C 36. Minimum panel thickness: 16 mm [5/8"].
Provide Type X panels in fire-rated assemblies. Provide moisture resistant panels at locations
subject to moisture. Provide abuse-resistant panels where indicated in functional and area
requirements. Joint treatment: ASTM C 475. Screws ASTM C 646. Drywall installation: ASTM
C 840.
5-5.3.3
Ceramic Tile. Comply with ANSI A 137.1 and the recommendations of Tile Council
of America (TCA) Handbook For Ceramic Tile Installation. Substrate for wall tile shall be mortar
setting bed or cement backer board (gypsum board is not acceptable). Provide marble
threshold under doors where a ceramic tile floor meets a different floor finish.
5-5.4
Ceilings. Comply with requirements of applicable codes. Non-combustible
construction is preferable, even where combustible materials are allowed by code. Ceiling
finish materials shall be as specified in functional and area requirements listed in Chapter 2 of
the Statement of Work.
5-5.5
Interior Doors and Frames. Provide hollow metal doors, or flush wood solid core
doors at UEPH and administrative spaces. Provide hollow metal doors at COF supply spaces.
All frames shall be hollow metal.
5-5.5.1
Wood Doors. Provide flush wood solid core doors complying with National Wood
Window and Door Association (NWWDA) I.S.-1A. Stile edges shall be non-finger jointed
hardwood compatible with face veneer. Provide American Woodwork Institute (AWI) Grade A
hardwood face veneer for transparent finished doors; provide AWI Sound Grade hardwood face
veneer for painted doors. Transparent finished doors are preferred.
5-5.5.2
Hollow Metal Doors. Comply with ANSI A250.8/SDI 100. Doors shall be Level 2,
physical performance Level B, Model 2; factory primed. Anchors and accessories shall be zinc
SOW-110