UFC 4-740-02
26 September 2006
TABLE 4-9. CLASSROOMS/TRAINING ROOMS
This space is used as a classroom for conducting programmed fitness and health
Description/
related training.
Usage
Service Exception: For Air Force and Marine Corps facilities that include a Health
and Wellness Center, this classroom will be shared with that component and should be
easily accessible from the Health and Wellness Center.
2.74 m (9 ft.) minimum.
Min. Ceiling Ht.
Walls. Painted gypsum wallboard or vinyl wall covering.
Floor. VCT with vinyl base. Consider carpet.
Ceiling. ACP.
Consider providing a small sink (see Casework).
Plumbing
20 C (68 F) minimum, 26 C (78 F) maximum.
HVAC
Provide system per Section 3-5.3.
Fire Protection
Power
Provide outlets per code and additional outlets necessary to operate dedicated
equipment.
Lighting
540 Lux (50 ft. candles) ambient lighting from fluorescent fixtures. Dimmable recessed
lighting.
CCTV. Provide outlets as required for coverage.
Communication
CATV/Internal Video. Provide one outlet.
PA/Audio. Provide a speaker.
Telephone. Provide one line.
Data. Provide a minimum of one outlet. Consider providing additional outlets for
training purposes.
Security. None required.
Solid-surface countertop; see Paragraph 3-4.1 for length criteria. Provide lockable wall
Casework/
and base cabinets. Provide a storage closet for training materials and AV cart.
Built-in
Provide an electrically operated retractable screen and a built-in computer projector.
Equipment
Provide CCTV cameras per the outlet count.
Furnishings
Fixtures &
Provide tables, chairs, bulletin board with tack surface and dry-erase board.
Equipment
Consider providing overhead projector, printer, TV, VCR, and DVD player.
(FF&E)
Special
Provide a minimum sound transmission coefficient (STC) rating of 50 to 55.
Requirements
Provide a vision panel in the door.
Service Exception: For the Air Force, provide a moveable partition to divide the large
classroom into two spaces.
For use during project execution by the appropriate Service agency
Staff.
Occupancy
Customers.
Min. net m2 (ft2)
4-11