Design Guide: Band Training Facilities
DG-1110-3-119
Space Criteria
March 1983
Mechanical space must be accessible from outside the
q
building only, for use by the Facility Engineers.
Mechanical spaces should not be adjacent to any music
q
practice or rehearsal rooms. If this is unavoidable, ducts
must not pass directly into such rooms.
D. Furnishings and Equipment
Deep laundry-type sink in janitor's closet for building
q
cleaning and maintenance.
4-14 Arms Room
(Optional Function)
A. Use.
Storage of weapons for use by the band unit. This is
q
an optional function, not necessarily included in the
Band Training Facility.
B. Size and Technical Recommendations
Not part of typical band facility space program; if included,
q
this requires additional square footage.
Space requirement, approximately 40 NSF for a 45 per-
q
son band, 50 NSF for a 65 person band; see AR 190-11
for specific requirements.
Special security requirements apply to design of this
q
space; see AR 190-11.
C. Relationships
Should be included as part of Storage or Unit Supply
q
area as a separate, secure enclosed space.
Access is limited under special security requirements.
q
B. 65 person new construction example
4-15 Mail Room
4-13 Maintenance and
(Optional Function)
Mechanical Spaces
A. Use.
A. Use.
Sorting and distribution of mail for band personnel.
q
Storage for building cleaning supplies and support for
q
This is an optional function, not necessarily included
janitorial services.
in the Band Training Facility.
Equipment for mechanical, plumbing and electrical
q
systems.
B. Size and Technical Recommendations
Not part of typical band facility space program; if
B. Size and Critical Dimensions
q
included, this requires additional square footage.
Janitor's Closet: 50 NSF.
q
Individual mail boxes for each person must be provided,
q
Mechanical Space: typically 5% of overall building area.
plus adequate counter-space for sorting and loading in
q
the mail boxes.
C. Relationships
Space requirement, approximately 30 NSF for a 45 per-
q
son band, 35 NSF for a 65 person band.
Janitor's closet should be reasonably convenient to
q
Special security requirements apply to design of this
all parts of the building for ease of maintenance
q
space; see United States Postal Service Publication
operations. Closeness to toilet area is recom-
17.
mended for plumbing economy.
4-19