\ Furniture
Folding tables and chairs, or fold-up tables with attached stools or attached
benches
Mobile floor lectern
Adjustable stool with or without arms
equipment
Public address system with speakers and microphone outlets contractor-
supplied
Ordinary hazard sprinklers
Marker boards and projection screens may be added if Tenants desire
special features or considerations
Typically must be separated from adjacent spaces with rated wall.
If the ceiling is not suspended acoustical tile, the acoustics of the room must be
addressed
If operable partition is included, provide structural support and stacking space
If fold-up tables with attached stools or benches are provided, ensure that door
to chair storage is tall enough to accommodate the height of these items
folded into their mobile configuration
If fold-up tables with attached stools or benches are provided, provide a few
folding tables and stacking chairs to be used as registration tables,
banquet tables, etc. also provide table dollies and chair caddies for these
items./1/
4-2.9
Chair and Table Storage
4-2.9.1 This space is for the storage of the assembly hall tables and chairs when not
in use.
||content||
\ The PA system for the assembly hall is also typically located here. The PA
system shall have wireless clip-on type microphones./1/
4-2.9.2 This space should not be used for mechanical equipment or electrical panels
due to the potential for damage to them or obstruction by the stored furniture.
Figure 4-12
4-2.9.3 Space Design Information
Chair and Table Storage
General/Code
Size 10% times assembly hall authorized area
Occupancy business
Occupancy count 1 person per 100 sf (9.3 sq m)
Architectural/Interiors
Minimum STC rating 40
Ceiling height 10 ft (3050 mm)
Floor \ VCT/2/
Base rubber
Walls painted gypsum board; painted CMU as alternative
Ceiling suspended acoustical ceiling tile (ACT)
Trim wall guard to protect walls
Lockset storeroom on active leaf; flush bolts inactive