Project Name
Project No. ___________
UFC 4-214-02, TEMF, 24 July 03
CONTRACTOR QUALITY CONTROL REQUIREMENTS
A plan for material storage and protection.
The plan for review, evaluation, and Offeror Quality Control of the Design Submittals prior
to Government receipt.
The plan for review of submittals and extensions of design.
Of particular interest is the
role of the Designer of Record in all design and construction progress.
Procedures for involving Key Subcontractors in the design development.
Procedures for successful integration of the Offeror's Quality Control Program with the
Government's Quality Assurance Program.
i. Technical Data Requirements for Proposals. The following technical data shall be submitted as part of
the formal Design-Technical Information Phase 2 proposal. Proposals shall include graphic descriptions
of the design included in the basic proposal clearly indicated as such. All alternate designs shall be
graphically described on separate drawings from the basic proposal. Offerors are advised that the
required data listed below will be utilized for technical review and evaluation and used for determination of
a "Quality Rating" by a Technical Evaluation Team. Materials indicated in the design/construction criteria,
but not indicated in the offeror's specifications, will be assumed to be included and a part of the proposal.
(1) Design drawings.
Provide an index of drawings. If required drawings are common for more than
one type of building, indicate so on the drawing. Do not provide foundation plans or structural, civil,
plumbing, mechanical, or electrical details. The proposal design drawings shall provide the information
as indicated in the following tables:
SITE DESIGN
Drawing Type / Scale
Show This Information
Area Site
Spatial and functional arrangement of all SOW requirements
Development Plan
Adjacent land uses and historical or environmental conditions
1:1000
Note1
Existing Contours
Proposed contours at 1 m intervals [3'].
Drainage and water retention ponds (if utilized)
Vehicular and pedestrian circulation
Demolition Plan
All site amenities, structures, or features to be removed or
1:500
retained.
Site Plan
Layout for all site requirements.
1:500
00110 - 15