Project Name
Project No. ___________
UFC 4-721-11.1, UEPH Complexes, 26 Nov 01
SITE DESIGN
Drawing Type / Scale
Show This Information
Utility Plan
All site utility requirements.
1:500 [1"=80']
Site lighting.
Primary cable routing (new and existing).
Cable television and telephone routing.
Off-Site Electrical Plan
Location of primary supply point of take-off.
1:5000 [1"=400']
Existing electrical lines, both overhead and
Scale as required
underground, properly identified.
(If applicable)
New construction tie-in to on-site electrical distribution system.
Note1: Drawings shall be dimensioned to show building separations, set back, etc.
Note2: Metric Scales are preferred, however, inch pound scales may continue to be used
only if they enhance competition.
BUILDING DESIGN
Drawing Type / Scale
Show This Information
Floor Plans
Overall dimensions.
1:50 [1/4" = 1'-0"]
Room description with dimensions and areas.
or
Appliances and built-in features
1:100 [1/8"=1'-0"]
Plumbing fixtures and vanities.
(For each building type)
Kitchenette layout
Door swings.
Patio (If Applicable).
Service area (Delineate equipment service req. areas)
Mechanical/Electrical/Service Spaces
Calculated gross and net floor areas.
Floor Plan
Life Safety Plan, include the following:
1:50 [1/4"=1'-0"]
- Exit Distances
or
- Rated Assemblies
1:100 [1/8"=1'-0"]
- Building Classification
(For each building type)
- Space Classifications
Typical
Show all sides.
Exterior Elevations
1:100 [1/8"=1'-0"]
(For each building type)
Typical
Kitchenettes and Toilet Spaces.
Interior Elevations
1:50 [1/4"=1'-0"]
(For each building type)
00110 - 15