UFC 4-740-03
1 NOVEMBER 2002
TABLE 3-7. TRAINING ROOMS/CLASSROOMS
These rooms provide meeting and instructional space for facility users. Views to the
Description/
outside and/or inside activities are important. These rooms may serve as an after-hour
Usage
gathering point for remote activities. Direct access to the outside and controlled
access to the interior will support the gathering function.
2.74 m (9 ft.) minimum.
Min. Ceiling Ht.
Walls. Painted gypsum wallboard.
Floor. VCT with vinyl base.
Ceiling. ACP.
Consider providing a small sink (see Casework)
Plumbing
20 C (68 F) minimum, 26 C (78 F) maximum.
HVAC
Building system.
Fire Protection
Power
Provide outlets per code and additional outlets necessary to operate dedicated
equipment.
Lighting
540 Lux (50 ft. candles) ambient lighting from fluorescent fixtures. Dimmable recessed
lighting.
CCTV. None required.
Communication
CATV/Internal Video. Provide one outlet.
PA/Audio. Provide one speaker.
Telephone. Provide one outlet.
Data. Provide one outlet.
Security. None required.
None required. Consider providing kitchenette area with a counter, sink, and cabinets.
Casework
Tables and chairs.
Furnishings
Fixtures &
TV with video and DVD capability.
Equipment
(FF&E)
Window shade control (blackout).
Marker board.
STC 49 minimum at perimeter walls and partitions.
Special
Requirements
3-10