UFC 4-171-05
1 January 2005
with change 25 October 2006
equipment
special features or considerations
Power, conduit and boxes for IDS system to be provided by the Government
Though not a requirement, Tenants normally prefer no windows in this
space
4-2.38
Distance Learning Center
4-2.38.1 This space is provided, when authorized, to allow delivery of remote training
and education resources. An authorization of 800 sf (74 sq m) is provided for each
multiple of 12 students, and there may be an associated office for a contract operator/
instructor.
4-2.38.2 The space will be similar to a computer learning lab, with voice/data links. The
Using Service will provide and install all equipment, hardware and software; the
designer must obtain the specifications, and coordinate the design of the mechanical
and electrical building systems required to support the space and equipment.
4-2.38.3 Space Design Information - similar to Classroom above; designer must verify
whether projection screens, marker boards, map rails and similar accessories are
required.
4-2.39
Male and Female Toilets and Showers
4-2.39.1 Toilet rooms should be provided on each floor, and may be distributed
throughout larger buildings for personnel convenience. The total fixture count should be
based on the tables in Appendx F for the maximum drill weekend. If local codes require
more fixtures, review with the Using Service. Modesty screening should be provided at
toilet room entries.
4-2.39.2 Shower rooms are provided primarily for weekend drill and physical training
purposes, but will also serve some sustainable design goals. Shower rooms should be
associated with a toilet room, but only one shower room for each sex should be
provided. All showers will be individual units; no gang showers. Standard shower stall is
36 in x 36 in (900 mm by 900 mm); accessible stalls may be 40 in x 40 in (1000 mm by
1000 mm) or 36 in x 60 in (900 mm by 1500 mm).
4-2.39.3 Space Design Information
General/Code
Size varies
Occupancy business
Occupancy count 1 person per 100 sf (9.3 sq m)
Architectural/Interiors
Minimum STC rating 40
Ceiling height 8 ft - 8 in (2600 mm) minimum
Floor ceramic tile; open rubber tile at showers
122