UFC 4-171-05
1 January 2005
with change 25 October 2006
electrical
Lighting 50 fc with dual-level switching; provide dimmers
\ - Provide receptacle for ceiling mounted overhead projector.
- Provide duplex receptacle in floor under the table /2/
Voice/data voice/data duplex on each wall and in floor under the table
\ - Provide conduit from the overhead projector location to a wall box on
wall opposite proposed screen location /2/
Furniture
Large wood conference table; small wood conference tables optional
High-back upholstered chairs with adjustable seat height, fixed arms, and swivel
base at conference table
Sled-based chairs around perimeter of room
Full-height floor lectern with microphone and light
Adjustable stool with or without arms optional
Credenza
equipment
Powered projection screen wired to lectern to allow computer screen to be
projected
Electronic presentation "smart board" with printing capabilities, enclosed
Two inch (2") map rail on one (1) wall
Map rail to include end stops and hanger clips
Verify with Tenants if CATV, LCD projection, video teleconferencing, etc., are
desired (TV and projector by Tenants) ACSIM-AR approval is required
special features or considerations
Optional built-in casework may be appropriate for storage and counter space
Provide chair rail around entire room
Provide structural support for ceiling mounted projector (projector to be provided
by Tenant)/1/
\ Provide blocking in ceiling for an overhead projector./2/
4-2.35
Drafting Room
4-2.35.1 This space is used for manual or electronic drafting training and operations,
printing, and storage of drawings and media. In most cases it should be set up for one
manual and one CAD drafting station. Designer should verify typical drafting practice
with Tenants.
4-2.35.2 Space Design Information
General/Code
Size 250 sf (23.25 sq m)
Occupancy business
Occupancy count 2 people
Architectural/Interiors
Minimum STC rating 40
Ceiling height 8 foot - 8 in (2600 mm) minimum
118