UFC 4-171-05
1 January 2005
with change 25 October 2006
Figure 4-28
Physical Readiness Training Room
4-2.36.4 Space Design Information
General/Code
Size varies
Occupancy business
Occupancy count 1 person per 100 sf (9.3 sq m)
Architectural/Interiors
Minimum STC rating 40
Ceiling height 8 foot - 8 in (2600 mm) minimum
Floor cushioned athletic-type flooring; VCT as an alternative
Base rubber
Walls painted gypsum board; painted CMU as an alternative
Ceiling suspended acoustical ceiling tile (ACT)
Trim none
Lockset classroom
Mechanical
Heating, occupied 68 degrees F (20 C); maintained 55 degrees F (13 C)
Cooling, occupied 78 degrees F (25 C); maintained ambient
Ventilation 20 cu ft per minute (10 L/S) per person minimum; sufficient
ventilation for rigorous activity do not recirculate to other spaces
electrical
Lighting 30 fc
Receptacles convenience duplex; outlets for powered equipment
120